Explore Insights New Insights Help
Sign Up for a Free Account Log In

Insight Maker

Biomedical Models

These models and simulations have been tagged “Biomedical”.

Related tagsHealth CareThe Body And SelfDiabetes

Insight diagram

WIP Physiological circuits insight integrated with other articles on inflammation fibrosis and innate immunity

Multiscale integration of Inflammation and fibrosis
Profile photo Geoff McDonnell
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Modificación guía 8
Profile photo Karla Argueta
Insight diagram
WIP Extension of the simplified Glucose minimal model (IM) as described in Ch 2 of Uri Alon's System Medicine Book  Values from Mohammed 2019 article. Copied from Mark Heffernan's Stella model (to be hosted)
BIG Beta cell Insulin Glucose Model
Profile photo Geoff McDonnell
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Kevin Josué Argueta Argueta
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Karla Argueta
Insight diagram

Modificacion con propositos didacticos del modelo: 

Created in James Madison University's ISAT 341 Simulation and Modeling course by Joseph Straub and Andrew Funkhouser. Based on Mark Heffernan's Glucose-Insulin Insight Maker


Glucose Insulin Model Info:

Translated from Hormone.stm in Dynamic Modeling in the Health Sciences James L hargrove, Springer 1998, Ch 24 p255-261, by Mark Heffernan.

Clone of Glucose-Insulin Model in Type 1 Diabetes
Profile photo ALEXIS RAMOS
3 9 months ago
Insight diagram

Modificacion con propositos didacticos del modelo: 

Created in James Madison University's ISAT 341 Simulation and Modeling course by Joseph Straub and Andrew Funkhouser. Based on Mark Heffernan's Glucose-Insulin Insight Maker


Glucose Insulin Model Info:

Translated from Hormone.stm in Dynamic Modeling in the Health Sciences James L hargrove, Springer 1998, Ch 24 p255-261, by Mark Heffernan.

modificacion 2
Profile photo ALEXIS RAMOS
9 months ago
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Jon Sanchez
Insight diagram
WIP based on Uri Alon's 2024-5 course on Systems Aging
Systems Aging
Profile photo Geoff McDonnell
10 months ago
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Karla Argueta
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo steffany flores
Insight diagram

Modificacion con propositos didacticos del modelo: 

Created in James Madison University's ISAT 341 Simulation and Modeling course by Joseph Straub and Andrew Funkhouser. Based on Mark Heffernan's Glucose-Insulin Insight Maker


Glucose Insulin Model Info:

Translated from Hormone.stm in Dynamic Modeling in the Health Sciences James L hargrove, Springer 1998, Ch 24 p255-261, by Mark Heffernan.

modificacion 1
Profile photo ALEXIS RAMOS
9 months ago
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Gabriela Barrera Amaya
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Stephen Aguilar
Insight diagram

Created in James Madison University's ISAT 341 Simulation and Modeling course by Joseph Straub and Andrew Funkhouser. Based on Mark Heffernan's Glucose-Insulin Insight Maker


Glucose Insulin Model Info:

Translated from Hormone.stm in Dynamic Modeling in the Health Sciences James L hargrove, Springer 1998, Ch 24 p255-261, by Mark Heffernan.

Clone of Glucose-Insulin Model in Type 1 Diabetes
Profile photo Joshua Pineda
9 months ago
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo David Rodriguez
Insight diagram

Modificacion con propositos didacticos del modelo: 

Created in James Madison University's ISAT 341 Simulation and Modeling course by Joseph Straub and Andrew Funkhouser. Based on Mark Heffernan's Glucose-Insulin Insight Maker


Glucose Insulin Model Info:

Translated from Hormone.stm in Dynamic Modeling in the Health Sciences James L hargrove, Springer 1998, Ch 24 p255-261, by Mark Heffernan.

modificacion 3.
Profile photo ALEXIS RAMOS
9 months ago
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Rodrigo Torres
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo steffany flores
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Kevin Josué Argueta Argueta
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo steffany flores
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo vidya veldore
Insight diagram
Healht
kadyr
Profile photo Кадыр Отепберген
9 months ago
Insight diagram

Minimal model of glucose kinetics by Bergman, used to calculate insulin sensitivity from an Intravenous Glucose Tolerance Test (IVGTT). Plasma insulin I(t) enters a remote compartment X(t) where it is active in accelerating glucose G(t) disappearance into the periphery and liver, and inhibiting hepatic glucose production. Adapted from Minimal Models for Glucose and Insulin Kinetics: A Matlab implementation by Natal van Riel, Eindhoven University of Technology 2004 by Mark Heffernan.

Clone of Glucose minimal model
Profile photo Frankling Espinoza
  • ‹ previous
  • ...
  • 7
  • 8
  • 9
  • 10
  • next ›
contact@insightmaker.com | Terms of Use | Privacy Policy
Copyright 2026.   Built with ☘️ in Ireland. GitHub logo Open-Source JavaScript Simulation Library